Copley Controls Serial Encoder Guia do Utilizador Página 107

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 180
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 106
Xenus XTL User Guide Quick Setup with CME 2
Copley Controls Corp. 99
5.7.3: Digital Position Input
For more information, see Digital Input (p. 18).
5.7.3.1 Click Digital Position Inputs to open the Digital Position Input screen,
Configuration tab.
5.7.3.2 Set the options described below:
Option Description
Control Input
Pulse and Direction: One input takes a series of pulses as motion step commands, and
another input takes a high or low signal as a direction command.
Pulse Up / Pulse Down: One input takes each pulse as a positive step command, and
another takes each pulse as a negative step command.
Quadrature: A/B quadrature commands from a master encoder (via two inputs) provide
velocity and direction commands.
Increment
position on
Rising Edge: Increment position on the rising edge of the input pulse.
Falling Edge: Increment position on the falling edge of the input pulse.
Stepping
Resolution
Input Pulses: Number of Input Pulses required to produce output counts.
Range: 1 to 32,767. Default: 1.
Output Counts: Number of Output Counts per given number of input pulses.
Range: 1 to 32,767. Default: 1.
Invert Command When selected, inverts commanded direction.
5.7.3.3 In position mode, click the Trajectory Limits tab.