Homing Methods CME 2 User Guide
204 Copley Controls
E.3.7: Home Switch
Direction of Motion: Positive
Home is the home switch transition. Initial direction of motion is positive if the home switch
is inactive. If a limit switch is activated before the home switch transition, an error is
generated.
H
Home Switch
Direction of Motion: Negative
Home is the home switch transition. Initial direction of motion is negative if the home
switch is inactive. If a limit switch is activated before the home switch transition, an error is
generated.
H
Home Switch