Xenus Plus User Guide Wiring
Copley Controls 110
4.10.3: Isolated Control XE2/XP2/800-1808 (J9)
J9 is a 26 position male D-sub connector used for isolated controls
Mating Connections
26 Position, High-Density D-Sub Female Solder
Style Connector
Solder style connector included in Connector Kits XE2-CK and XP2-CK.
Pin connections for the bulkhead connector on the drive are shown here:
XE2/XP2/800-1808 Pin Description
Optically isolated programmable input.
Common signal for first group of optically isolated programmable inputs (IN6-IN9)
Optically isolated programmable input.
Optically isolated programmable output negative signal.
Common signal for first group of optically isolated programmable inputs (IN16-IN19)
Optically isolated programmable input.
Optically isolated programmable output positive signal.
Optically isolated programmable output positive signal.