Xenus Plus User Guide Operational Theory
Copley Controls 38
2.10.3: XE2/800-1782 J7 Axis A/B: Drive Status Indicators
XE2/800-1782 J7 Axis A/B Drive Status Indicators
XE2/800-1782 indicator color/blink codes are described below.
Drive OK and enabled. Will run in response to reference inputs or EtherCAT commands.
Drive OK but NOT-enabled. Will run when enabled.
Positive or Negative limit switch active. Drive will only move in direction not inhibited by
limit switch.
Green flash twice
followed by a pause
STO is active, One or both STO inputs are de-energized. The drive is hardware & software
enabled but the PWM outputs cannot produce current in the motor when STO is active.
Transient fault condition. Drive will resume operation when fault is removed.
Latching fault. Operation will not resume until fault is cleared or drive is Reset.
Out
In
J7
J8
RUN-State of the ESM
L/A-Link activity
ERR-Errors
L/A-Link activity
A-Axis A
B-Axis B
Comentários a estes Manuais