Xenus Plus User Guide Wiring
Copley Controls 96
4.8: Network Ports
4.8.1: EtherCAT (XEL/XE2/800-1782)
Mating Connector
Dual RJ-45 sockets accept standard Ethernet cables. The IN port connects to a master, or to the
OUT port of a device that is ‘upstream’ between the Xenus Plus and the master. The OUT port
connects to ‘downstream’ nodes. If Xenus Plus is the last node on a network, only the IN port is
used. No terminator is required on the OUT port.
Pin Description*
*Table applies to both EtherCAT connectors
EtherCAT Bus Wiring Diagram
The XEL drive uses connector J7. The XE2 drive uses connector J8.
Drive Jx
TX +
TX
-
RX +
EtherCAT Network ("In")
Jx-1
Jx-2
Jx-4
Jx-3
Jx-5
Jx-6
Jx-7
Jx-8
Jx-1
Jx-2
Jx-4
Jx-3
Jx-5
Jx-6
Jx-7
Jx-8
Opto-isolation
RX -
TX +
TX
-
RX +
RX -
EtherCAT Network ("Out")
Opto-isolation