Xenus Plus User Guide Wiring
Copley Controls 118
…Pin Description, continued:
Encoder +5 Vdc power supply output.
Total load current on J10-6, J10-17, and J8-20 not to exceed 400 mA.
Signal and +5 Vdc ground.
Signal and +5 Vdc ground.
Quad A/B Incremental Encoder Wiring Diagram
In XEL/XPL/XML there are two encoder +5V outputs at 400 mA each, and in the XE2/XP2/800-1808 there
are 4 encoder +5V outputs at 500 mA each.